Energy-efficient multistage nozzle design
It has a very strong suction capacity
A variety of specifications of air supply port and vacuum port
Energy-saving system(ES) is optional
AM 25L - AD - N - A - ES
① ② ③ ④ ⑤ ⑥
① Series | ② Specification | ③ Connection plate | ④ Sealing | ⑤ Non-return valve | ⑥ Control device |
AM - Universal type | 25L 50L 75L | D | N - NBR | Nil - Default, without non-return valve | Nil - Default, without |
(-92kPa) | 100L 125L 150L | B | E - EPDM | A - With a non-return valve | control device |
AL - Large vacuum flow type | 25 50 75 | AD | F - Fluorine rubber | ES - Energy-saving system | |
(-81kPa) | 100 125 150 | E | only for AM-25L/50L | ||
AH - High vacuum level type | 40 120 | (Refer to table1) | AL-25/50 | ||
(-100.8kPa) | AH-40 |
Technical parameters
Model | Rated air supply pressure bar | Max. vacuum level -kPa | Max. vacuum flow NL/min | Air consumption NL/min | Noise level dB(A) | Working temperature ℃ | Weight g | Recommendedhosedia. mm (Hose outer dia.) Air supply port | Recommendedhosedia. mm (Wired hose inner dia.) vacuum port V |
AL25 | 6 | 81 | 360 | 105 | 81 | -10~80 | 675 | φ8 | φ19 |
AL50 | 6 | 81 | 640 | 215 | 81 | -10~80 | 675 | φ10 | φ19 |
AL75 | 6 | 81 | 850 | 320 | 81 | -10~80 | 837 | φ10 | φ25 |
AL100 | 6 | 81 | 990 | 390 | 82 | -10~80 | 837 | φ10 | φ25 |
AL125 | 6 | 81 | 1,170 | 480 | 82 | -10~80 | 1,075 | φ12 | φ32 |
AL150 | 6 | 81 | 1,230 | 620 | 81 | -10~80 | 1,075 | φ12 | φ32 |
AH40 | 6 | 99.8 | 150 | 155 | 81 | -10~80 | 675 | φ10 | φ19 |
AH120 | 6 | 100.8 | 530 | 440 | 81 | -10~80 | 837 | φ12 | φ19 |
AM25L | 3.4 | 92 | 360 | 116 | 80 | -10~80 | 675 | φ8 | φ19 |
AM50L | 3.4 | 92 | 600 | 230 | 81 | -10~80 | 675 | φ8 | φ19 |
AM75L | 3.4 | 92 | 760 | 365 | 81 | -10~80 | 837 | φ10 | φ25 |
AM100L | 3.4 | 92 | 850 | 445 | 81 | -10~80 | 837 | φ10 | φ25 |
AM125L | 3.4 | 92 | 1,150 | 545 | 82 | -10~80 | 1,075 | φ12 | φ32 |
AM150L | 3.4 | 92 | 1,200 | 655 | 82 | -10~80 | 1,075 | φ12 | φ32 |
AM25L | 6 | 89 | 420 | 185 | 80 | -10~80 | 675 | φ8 | φ19 |
AM50L | 6 | 89 | 700 | 370 | 81 | -10~80 | 675 | φ8 | φ19 |
AM75L | 6 | 89 | 950 | 610 | 81 | -10~80 | 837 | φ10 | φ25 |
AM100L | 6 | 89 | 1,010 | 720 | 81 | -10~80 | 837 | φ10 | φ25 |
AM125L | 6 | 89 | 1,400 | 780 | 82 | -10~80 | 1,075 | φ12 | φ32 |
AM150L | 6 | 89 | 1,500 | 810 | 82 | -10~80 | 1,075 | φ12 | φ32 |
Vacuum flow(NL/min) at different vacuum levels(-kPa)
Model | Air supply pressure bar | Air consumption NL/min | 0 | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | Max. vacuum level -kPa |
AM25L | 3.4 | 116 | 360 | 180 | 115 | 80 | 43 | 30 | 22.5 | 15.5 | 7.5 | 21.2 | 92 |
AM50L | 3.4 | 230 | 600 | 320 | 250 | 135 | 75 | 60 | 46 | 30 | 13 | 1.5 | 92 |
AM75L | 3.4 | 365 | 760 | 445 | 340 | 175 | 110 | 85 | 70 | 43 | 20 | 1.8 | 92 |
AM100L | 3.4 | 445 | 850 | 550 | 430 | 280 | 145 | 115 | 85 | 60 | 28 | 2.2 | 92 |
AM125L | 3.4 | 545 | 1,150 | 760 | 530 | 350 | 180 | 148 | 115 | 78 | 34.5 | 3.5 | 92 |
AM150L | 3.4 | 655 | 1,200 | 830 | 550 | 360 | 215 | 170 | 130 | 90 | 36 | 5 | 92 |
AM25L | 6 | 185 | 420 | 240 | 125 | 100 | 82 | 65 | 38 | 12.5 | 3.5 | - | 89 |
AM50L | 6 | 370 | 700 | 510 | 290 | 195 | 160 | 115 | 70 | 22 | 8 | - | 89 |
AM75L | 6 | 610 | 950 | 710 | 380 | 285 | 230 | 170 | 100 | 32 | 11 | - | 89 |
AM100L | 6 | 720 | 1,010 | 800 | 460 | 385 | 310 | 215 | 125 | 42 | 15.5 | - | 89 |
AM125L | 6 | 780 | 1,400 | 1,120 | 560 | 490 | 355 | 260 | 150 | 50 | 25 | - | 89 |
AM150L | 6 | 810 | 1,500 | 1,110 | 630 | 560 | 385 | 315 | 210 | 65 | 26 | - | 89 |
Evacuation time(s/L) to reach different vacuum levels(-kPa)
Model | Air supply pressure bar | Air consumption NL/min | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | Max. vacuum level -kPa |
AM25L | 3.4 | 116 | 0.022 | 0.060 | 0.110 | 0.210 | 0.400 | 0.650 | 0.950 | 1.600 | 4.000 | 92 |
AM50L | 3.4 | 230 | 0.014 | 0.031 | 0.060 | 0.100 | 0.200 | 0.340 | 0.500 | 0.800 | 2.500 | 92 |
AM75L | 3.4 | 365 | 0.012 | 0.029 | 0.058 | 0.095 | 0.180 | 0.310 | 0.460 | 0.890 | 1.500 | 92 |
AM100L | 3.4 | 445 | 0.010 | 0.025 | 0.043 | 0.075 | 0.110 | 0.190 | 0.270 | 0.450 | 1.200 | 92 |
AM125L | 3.4 | 545 | 0.006 | 0.015 | 0.029 | 0.052 | 0.085 | 0.145 | 0.202 | 0.330 | 1.000 | 92 |
AM150L | 3.4 | 655 | 0.005 | 0.013 | 0.027 | 0.045 | 0.070 | 0.105 | 0.230 | 0.460 | 0.900 | 92 |
AM25L | 6.0 | 185 | 0.018 | 0.050 | 0.080 | 0.018 | 0.250 | 0.400 | 0.620 | 1.550 | - | 89 |
AM50L | 6.0 | 370 | 0.010 | 0.022 | 0.048 | 0.080 | 0.110 | 0.200 | 0.350 | 0.780 | - | 89 |
AM75L | 6.0 | 610 | 0.009 | 0.019 | 0.045 | 0.075 | 0.130 | 0.180 | 0.310 | 0.700 | - | 89 |
AM100L | 6.0 | 720 | 0.007 | 0.018 | 0.038 | 0.055 | 0.080 | 0.120 | 0.190 | 0.470 | - | 89 |
AM125L | 6.0 | 780 | 0.005 | 0.013 | 0.026 | 0.045 | 0.062 | 0.115 | 0.194 | 0.560 | - | 89 |
AM150L | 6.0 | 810 | 0.003 | 0.009 | 0.014 | 0.030 | 0.060 | 0.095 | 0.200 | 0.800 | - | 89 |
Vacuum flow(NL/min) at different vacuum levels(-kPa)
Model | Air supply pressure bar | Air consumption NL/min | 0 | 10 | 20 | 30 | 40 | 50 | 60 | 70 | Max. vacuum level -kPa |
AL25 | 6 | 105 | 360 | 196 | 135 | 85 | 45 | 36 | 27 | 17 | 81 |
AL50 | 6 | 215 | 640 | 320 | 205 | 145 | 95 | 65 | 45 | 25 | 81 |
AL75 | 6 | 320 | 850 | 430 | 320 | 190 | 130 | 105 | 65 | 40 | 81 |
AL100 | 6 | 390 | 990 | 580 | 460 | 300 | 185 | 130 | 95 | 52 | 81 |
AL125 | 6 | 480 | 1,170 | 720 | 541 | 350 | 200 | 150 | 125 | 65 | 81 |
AL150 | 6 | 620 | 1,230 | 760 | 560 | 410 | 210 | 160 | 148 | 85 | 81 |
Evacuation time(s/L) to reach different vacuum levels(-kPa)
Model | Air supply pressure bar | Air consumption NL/min | 10 | 20 | 30 | 40 | 50 | 60 | 70 | Max. vacuum level -kPa |
AL25 | 6 | 105 | 0.03 | 0.06 | 0.1 | 0.2 | 0.39 | 0.58 | 0.87 | 81 |
AL50 | 6 | 215 | 0.018 | 0.039 | 0.066 | 0.12 | 0.2 | 0.31 | 0.51 | 81 |
AL75 | 6 | 320 | 0.01 | 0.02 | 0.04 | 0.08 | 0.12 | 0.2 | 0.31 | 81 |
AL100 | 6 | 390 | 0.008 | 0.017 | 0.032 | 0.05 | 0.09 | 0.13 | 0.22 | 81 |
AL125 | 6 | 480 | 0.006 | 0.016 | 0.026 | 0.045 | 0.078 | 0.11 | 0.18 | 81 |
AL150 | 6 | 620 | 0.005 | 0.014 | 0.024 | 0.04 | 0.071 | 0.1 | 0.16 | 81 |
Vacuum flow(NL/min) at different vacuum levels(-kPa)
Model | Air supply pressure bar | Air consumption NL/min | 0 | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 99 | Max. vacuum level -kPa |
AH40 | 6.0 | 155 | 150 | 145 | 105 | 52.5 | 27.5 | 20.5 | 15 | 8.5 | 5.5 | 3 | 0.2 | 99.8 |
AH120 | 6.0 | 440 | 530 | 420 | 265 | 141 | 85 | 65 | 45 | 33 | 21.5 | 6 | 0.5 | 100.8 |
Evacuation time(s/L) to reach different vacuum levels(-kPa)
Model | Air supply pressure bar | Air consumption NL/min | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 99 | Max. vacuum level -kPa |
AH40 | 6.0 | 155 | 0.04 | 0.08 | 0.18 | 0.32 | 0.64 | 1.3 | 1.8 | 2.6 | 3.9 | 9.8 | 99.8 |
AH120 | 6.0 | 440 | 0.02 | 0.04 | 0.08 | 0.14 | 0.25 | 0.38 | 0.66 | 1.08 | 3.6 | 8.5 | 100.8 |
Item | Model | Applicable vacuum generator |
Silencer | ZSA-G6M | AM25-50, AL25-50, AH40 |
Vacuum gauge | ZPMR-V | AM25-50, AL25-50, AH40 |
Sealing kits | AM50L-PK(1 +1 +2 s+2 Plugs) Upper sealing gasket Lower sealing gasket Small round gasket | AM25-50, AL25-50, AH40 |
Mounting accessory kit | AM100L (2 brackets+4 screws+1 φ8 one-touch fitting) | AM25-50, AL25-50, AH40 |
Silencer | ZSA-G6M | AM75-100, AL75-100, AH120 |
Vacuum gauge | ZPMR-V | AM75-100, AL75-100, AH120 |
Sealing kits | AM100L-PK(1 +2 s+2 s+4 Plugs) Upper sealing gasket Lower sealing gasket Small round gasket | AM75-100, AH120 |
Sealing kits | AL100-PK(1 +2 s+1 +1 + 4 Plugs) Upper sealing gasket Lower sealing gasket Small round gasket Big round gaske | AL75-100 |
Mounting accessory kit | AM100L (2 brackets+4 screws+1φ10one-touch fitting) | AM75-100, AL75-100, AH120 |
Silencer | ZSA-G8M | AM125-150, AL125-150 |
Vacuum gauge | ZPMR-V | AM125-150, AL125-150 |
Sealing kits | AM150L-PK(1 +3 s+1 +1 +6 Plugs) Upper sealing gasket Lower sealing gasket Small round gasket Big round gasket | AM125-150, AL125-150 |
Mounting accessory kit | AM150L(2 brackets+4 screws+1φ12 one-touch fitting) | AM125-150, AL125-150 |